Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
Back Issue    Advanced Search
This paper has been: browsed 4652times   downloaded 4355times  
Shared by: Wechat More
Wind-Thermal Environmental Characteristic of Multi-Variable Passive Enhanced Natural Ventilation System for High and Large Space Building
Author NameAffiliationPostcode
Lin Liu* School of Civil and Transportation Engineering,Guangdong University of Technology 510006
Haoran Huang School of Civil and Transportation Engineering,Guangdong University of Technology 510006
Chenghe Wu Architectural Design and Research Institute of Guangdong Province 510010
Liru Liu School of Civil and Transportation Engineering,Guangdong University of Technology 510006
jing Tian School of Civil and Transportation Engineering,Guangdong University of Technology 510006
Abstract:
Natural ventilation effects in high and large space buildings of tropical areas greatly affect the air conditioning energy consumption. Aiming at nearly zero energy building design, this paper mainly contributes to provide theoretical basis and reference for thermal comfortable air conditioning system design of high and large space buildings. Taking a theatre in Hainan as study object, a newly composite enhanced natural ventilation system is proposed by integrating the underground tunnel-based earth to air heat exchange system and the solar chimney. Ventilation quantity, air velocity and air temperature field, human vertical temperature gradient difference under 24 simulation working conditions are considered and analyzed by using ANSYS Fluent. For the underground tunnel, results show that Group Two with double underground tunnels and side air supply location shows its advantages in cooling effects and air supply uniformity. Then for the solar chimney, results show that the solar radiation intensity contributes to larger difference in transmission power and leads to different cooling effects. On the whole, the system under working condition No. 7 with 120 m long, side air supply, double underground tunnel and 20 m high, 1 m wide, 0.6° absorber plate angle solar chimney shows its priority in better comprehensive performance.
Key words:  natural ventilation  solar chimney  earth to air heat exchange system  energy conservation  thermal environment
DOI:10.11916/j.issn.1005-9113.2022039
Clc Number:TU82