Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:XIAO Hong-xia,SUN De-xing,LI Xin.Strong self-flushing technique for heat exchanger of sewage source heat pump system[J].Journal of Harbin Institute Of Technology(New Series),2010,17(1):8-12.DOI:10.11916/j.issn.1005-9113.2010.01.002.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 1048times   downloaded 571times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Strong self-flushing technique for heat exchanger of sewage source heat pump system
Author NameAffiliation
XIAO Hong-xia chool of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China 
SUN De-xing chool of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China 
LI Xin Architectural and Civil Engineering College, Shenyang University,Shenyang 110010, China 
Abstract:
To better remove the contamination on the surface of a heat-exchanger in urban sewage source heat pump system (USSHPS), this paper analyzes the feasibility of strong self-flushing on the basis of experiments and presents a new on-line self-flushing technique, which alternately flushes part of heat transfer tubes. In addition, operation principles and the structure of the new heat-exchanger are introduced and the feasible economical and technological cleaning plans are given by design calculation and scheme comparison. The result shows that keeping each tube washed for one minute with 5 m/s, the operating cost is lower than $5 and when one flushing pump alternately flushes 10-20 heat exchangers, the saved costs of flushing 10 tubes alternately are over 4 times of the increased costs.
Key words:  sewage  heat pump  heat exchanger  alternation  self-flushing
DOI:10.11916/j.issn.1005-9113.2010.01.002
Clc Number:TU831.4
Fund:

LINKS