Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:WEI Hua,WU Zhi-min,GUO Xia.Axial compressive behaviors of partial deteriorated strength concrete columns confined with CFRP[J].Journal of Harbin Institute Of Technology(New Series),2010,17(3):363-368.DOI:10.11916/j.issn.1005-9113.2010.03.013.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 709times   downloaded 571times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Axial compressive behaviors of partial deteriorated strength concrete columns confined with CFRP
Author NameAffiliation
WEI Hua State Key Laboratory of Coastal and Offshore Engineering,Dalian University of Technology,Dalian 116024,China
Henan Provincial Communications Quality Control Institute,Zhengzhou 450006,China 
WU Zhi-min State Key Laboratory of Coastal and Offshore Engineering,Dalian University of Technology,Dalian 116024,China 
GUO Xia State Key Laboratory of Coastal and Offshore Engineering,Dalian University of Technology,Dalian 116024,China 
Abstract:
This paper aims to present an effective method to partial deteriorated strength columns,and to investigate the mechanical behavior of the defect part. Five groups of 150×150 mm×mm plain square columns are cast; each specimen has two different strengths,the lower strength in the middle segment and higher strength in both ends. The lower strength is to simulate the status of partial deteriorated region. Different layers of CFRP sheets have been wrapped just on the lower strength part to gain the reinforcement with CFRP sheets,and to verify the practicability of partial confinement. Specimens are subjected to monotonic axial compression until failure. Axial load,axial and transverse strains are measured to compare the different behaviors between the two parts. Experimental results show that partial confinement can significantly enhance the strength and the ductility of the deteriorated strength part,then,the load capacity of the whole column can be increased subsequently. Test data indicate that the ultimate load of the confined column is higher than that of the original column without deterioration; partial confinement on weakness is a feasible approach.
Key words:  CFRP  concrete column  partial deteriorated strength  partial confinement
DOI:10.11916/j.issn.1005-9113.2010.03.013
Clc Number:TU375.3
Fund:

LINKS