Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:KANG Hua,HE Wen-jie,LIU Xiu-hong,WANG Dong.Fouling of organic fractionation on ultrafiltration membrane for drinking water treatment:a case study[J].Journal of Harbin Institute Of Technology(New Series),2010,17(6):819-823.DOI:10.11916/j.issn.1005-9113.2010.06.015.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 849times   downloaded 528times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Fouling of organic fractionation on ultrafiltration membrane for drinking water treatment:a case study
Author NameAffiliation
KANG Hua School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,China 
HE Wen-jie School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,China
Tianjin WaterWorks Group Company Ltd,Tianjin 300040,China 
LIU Xiu-hong Beijing Drainage Group Co.Ltd,Beijing 100044,China 
WANG Dong Changchun Water Group Co.Ltd,Changchun 130021,China 
Abstract:
The aim of this study was to obtain a better understanding of the range of organic molecular weight(MW)causing membrane fouling through the comparison between direct UF and in-line coagulation(without settling)/UF process.The experimental results indicated that,when raw water with organics was treated and the MW of more than half of the organics was less than 1 kDa,membrane fouling was rather serious by only UF and coagulation could improve the fouling for the treatment of raw water.Besides,coagulation/UF could remove organics in each region,and organics with MW greater than 30 kDa were the most possible matters causing membrane fouling,while organics with MW less than 1 kDa were impossibly responsible for membrane fouling due to few organics removed.Therefore,organics with MW greater than 30 kDa were the major factor of membrane fouling.
Key words:  fouling  molecular weight distribution  organics  Ultrafiltration
DOI:10.11916/j.issn.1005-9113.2010.06.015
Clc Number:TU991.2
Fund:

LINKS