Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:ZHANG Xin-yu,LI Xin,QIN Wu,XU Wen-wen,YUAN Yi-xing.Research on corrosion mechanism of water distribution system[J].Journal of Harbin Institute Of Technology(New Series),2011,18(1):121-125.DOI:10.11916/j.issn.1005-9113.2011.01.022.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 781times   downloaded 544times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Research on corrosion mechanism of water distribution system
Author NameAffiliation
ZHANG Xin-yu School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,China
School of Civil Engineering and Architecture,University of Jinan,Jinan,250022,China 
LI Xin School of Chemical Engineering & Technology,Harbin Institute of Technology,Harbin 150090,China 
QIN Wu School of Chemical Engineering & Technology,Harbin Institute of Technology,Harbin 150090,China 
XU Wen-wen School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,China 
YUAN Yi-xing School of Municipal and Environmental Engineering,Harbin Institute of Technology,Harbin 150090,China 
Abstract:
Pipes serving for water distribution system for different years in northern city,were chosen as objectives for study.The shape and component of corrosion scales were measured,and formation mechanism of corrosion was also analyzed.The corrosion mechanism of pipes was studied on the sides of electrochemistry and microbe.The solution to eliminate corrosion scales in water distribution system was also proposed.The results show that the specific surface areas of five corrosion scales are between 41.35 and 132.3 m2/g and the dimension of corrosion scales enlarge with the increase of serving age,which could induce the decrease of water flow cross-section.
Key words:  corrosion  water distribution system  water quality
DOI:10.11916/j.issn.1005-9113.2011.01.022
Clc Number:TG172
Fund:

LINKS