Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:XING Hai-yan,FAN Jiu-ming,XU Min-qiang,LI Qi.MMM testing and failure analysis of fastening bolts on reciprocating compressor cylinder cover[J].Journal of Harbin Institute Of Technology(New Series),2011,18(2):13-16.DOI:10.11916/j.issn.1005-9113.2011.02.003.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 783times   downloaded 555times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
MMM testing and failure analysis of fastening bolts on reciprocating compressor cylinder cover
Author NameAffiliation
XING Hai-yan School of Mechanical Science and Engineering,Northeast Petroleum University,Daqing 163318,China
School of Astronautics,Harbin Institute of Technology,Harbin 150001,China 
FAN Jiu-ming School of Astronautics,Harbin Institute of Technology,Harbin 150001,China 
XU Min-qiang School of Astronautics,Harbin Institute of Technology,Harbin 150001,China 
LI Qi School of Mechanical Science and Engineering,Northeast Petroleum University,Daqing 163318,China 
Abstract:
To avoid the serious accidents caused by the failure fastening bolts on reciprocating compressor cylinder cover,a new nondestructive testing(NDT) technology,metal magnetic memory(MMM) testing,was applied to safety evaluating and failure analyzing for the fastening bolts.Based on the dynamic stress calculation of the failure bolts,MMM testing was carried out at workshop.Given are the MMM stress distribution characteristics of the failure bolts and fracture faces.It has been found that the MMM signal variation amplitude of the crack transition zone in the fracture surface is minimal,that of the crack initiation zone is in the middle,and that of the tear fracture zone is maximal.The failure reasons were analyzed with MMM effect.The results of the metallographic examination showed that the validity and feasibility of MMM testing and failure analysis.This means MMM technology is a new,fast and validity method of failure analysis.
Key words:  metal magnetic memory testing  fastening bolts  failure analysis  stress calculation
DOI:10.11916/j.issn.1005-9113.2011.02.003
Clc Number:TH45
Fund:

LINKS