Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:CHEN Song-lai,WANG Huan-ding,FAN Cheng-mou,PAN Jing-long.Experimental study on full scale light frame wood house under repeated lateral load[J].Journal of Harbin Institute Of Technology(New Series),2011,18(3):125-130.DOI:10.11916/j.issn.1005-9113.2011.03.024.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 814times   downloaded 601times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Experimental study on full scale light frame wood house under repeated lateral load
Author NameAffiliation
CHEN Song-lai School of Civil Engineering,Harbin Institute of Technology,Harbin 150090,China 
WANG Huan-ding School of Civil Engineering,Harbin Institute of Technology,Harbin 150090,China 
FAN Cheng-mou School of Civil Engineering,Harbin Institute of Technology,Harbin 150090,China 
PAN Jing-long School of Civil Engineering,Harbin Institute of Technology,Harbin 150090,China 
Abstract:
In order to obtain a deeper understanding of the behavior of the structure under high wind load,this paper conducted an experimental study on a full-scale L-shaped single story light frame wood house under the uniform lateral load simulated using a gasbag.The investigation involved the performance of light frame wood structure after it experienced the repeated cyclic lateral wind load as well as the performance of the structure under the ultimate lateral load.Then,the study verified that light frame wood structure can resist repeated cyclic wind loads without observable degradation in stiffness during the anticipated serve life,and recommended shear wall percent drift restriction for lateral wind load design of wood structure in serviceability limit states is 1/400 drift,and in ultimate limit states is 1/80 drift.The conclusions of this paper can be benefit for the engineering practice of the light frame wood structures in high wind load regions.
Key words:  light frame wood house  simulated lateral wind load  full scale test  percent drift restriction
DOI:10.11916/j.issn.1005-9113.2011.03.024
Clc Number:
Fund:

LINKS