Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:GAO Jing-feng,ZHANG Yao-chun,WANG Hai-ming,YAO Qi-yu,JIN Lu.Static behavior of semi-rigid thin-walled steel-concrete composite beam-to-column joints with bolted partial-depth flush end plate:experimental study[J].Journal of Harbin Institute Of Technology(New Series),2011,18(5):91-102.DOI:10.11916/j.issn.1005-9113.2011.05.017.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 732times   downloaded 619times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Static behavior of semi-rigid thin-walled steel-concrete composite beam-to-column joints with bolted partial-depth flush end plate:experimental study
Author NameAffiliation
GAO Jing-feng School of Civil Engineering,Harbin Institute of Technology,Harbin 100590,China 
ZHANG Yao-chun School of Civil Engineering,Harbin Institute of Technology,Harbin 100590,China 
WANG Hai-ming China Electronics Engineering Design Institute,Beijing 100840,China 
YAO Qi-yu Beijing Institute of Architectural Design,Beijing 100045,China 
JIN Lu School of Civil Engineering,Harbin Institute of Technology,Harbin 100590,China 
Abstract:
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints.
Key words:  semi-rigid  thin-walled steel-concrete composite structures  beam-to-column joints  static behavior  experimental study
DOI:10.11916/j.issn.1005-9113.2011.05.017
Clc Number:TU398.9
Fund:

LINKS