Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:ZHOU Yong-chao,ZHANG Yi-ping.Global optimal control for regional sewer systems[J].Journal of Harbin Institute Of Technology(New Series),2011,18(5):143-148.DOI:10.11916/j.issn.1005-9113.2011.05.025.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 1035times   downloaded 571times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Global optimal control for regional sewer systems
Author NameAffiliation
ZHOU Yong-chao Institute of Municipal Engineering,College of Civil Engineering and Architecture,Zhejiang University,Hangzhou 310058,China 
ZHANG Yi-ping Institute of Municipal Engineering,College of Civil Engineering and Architecture,Zhejiang University,Hangzhou 310058,China 
Abstract:
In order to control combined system overflow (CSO) pollution of regional sewer systems in Shanghai,a global optimal control (GOC) is presented in this study.The GOC is based on the analysis of current situation and can maximize the utilization of the free storage of each sub systems and decrease the frequencies and durations of CSOs and flooding.A representative regional sewer system,which is located in the northwest of Shanghai and composed of sub systems of Zhenguang,Zhenru and Tongchuan,was taken as an example to demonstrate the efficiency of GOC with hydraulic model simulation test in the two representative scenarios (Scenario Ⅰ and Ⅱ).The results indicated that a great improvement in CSO emission is obtained by using the GOC in the two scenarios,and the CSO volume of three sub systems,Zhenru,Tongchuan and Zhenguang decreases to about 37.0%,38.3% and 35.7% in Scenario Ⅰ and 47.5%,51.8% and 63.5% in Scenario Ⅱ respectively.
Key words:  storm runoff  combined sewer overflow  optimization  simulation models
DOI:10.11916/j.issn.1005-9113.2011.05.025
Clc Number:TU992.4
Fund:

LINKS