Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2025 Vol.32
  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:Wen-Jing Dong,Tie-Jun Zhou,Run-Zhao Qi.Analysis of Energy Saving Reconstruction of Existing Campus Dormitories in Chongqing——Taking Dormitory Six on Campus B of Chongqing University as An Example[J].Journal of Harbin Institute Of Technology(New Series),2014,21(4):96-102.DOI:10.11916/j.issn.1005-9113.2014.04.015.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 1196times   downloaded 887times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Analysis of Energy Saving Reconstruction of Existing Campus Dormitories in Chongqing——Taking Dormitory Six on Campus B of Chongqing University as An Example
Author NameAffiliation
Wen-Jing Dong Chongqing University, Faculty of Architecture and Urban Planning, Chongqing 400045,China 
Tie-Jun Zhou Chongqing University, Faculty of Architecture and Urban Planning, Chongqing 400045,China
Key Laboratory of New Technology for Construction of Cities in Mountain Area, Chongqing 400045,China 
Run-Zhao Qi Chongqing University, Faculty of Architecture and Urban Planning, Chongqing 400045,China 
Abstract:
At present, a large number of historic buildings on campus are lack of energy-saving measures from the design time, especially the dormitories. And the reconstruction mostly focuses on functional reorganization or furniture replacement. However, energy efficiency design has not been paid enough attention, which leads to the high building energy consumption and the harsh physical environment. Based on the analysis of climatic characteristics of Chongqing area, taking Dormitory Six on campus B of Chongqing University as an example, the reconstruction of rooms on the top floor and West end are focused to guarantee the equal benefits of the dormitory environment. Through the simulation analysis of the software, on the basis of energy saving reconstruction of common maintenance structure, this thesis discusses the energy saving reconstruction methods and strategies of the existing campus dormitories, which are more suitable for the existing campus dormitories in Chongqing area.
Key words:  campus dormitories in Chongqing  energy-saving reconstruction  optimization reconstruction design  planted roof  greening of West walls
DOI:10.11916/j.issn.1005-9113.2014.04.015