Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:Hong-Peng Xu,Si Li.Saving Strategy and Simulation Analysis of Green Log Walls in Severe Cold Area[J].Journal of Harbin Institute Of Technology(New Series),2014,21(5):46-51.DOI:10.11916/j.issn.1005-9113.2014.05.008.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 1114times   downloaded 1111times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Saving Strategy and Simulation Analysis of Green Log Walls in Severe Cold Area
Author NameAffiliation
Hong-Peng Xu School of Architecture, Harbin Institute of Technology, Harbin 150001, China 
Si Li School of Architecture, Harbin Institute of Technology, Harbin 150001, China 
Abstract:
Log house is a traditional type of vernacular dwelling in Chinese cold area. It contains distinct regional characteristics and architectural cultures. In recent years, log house has come into vogue softly with the development of wood techniques. However, log houses expend too much wood materials. There are also many negative aspects of this type of wood building which go against the criteria of energy conservation, and its high prime cost hinders the application as well. To solve these problems, the paper emphasizes using more environmental standardized techniques which save cost at the same time, and put forward technical strategy to improve the log walls. The optimization schemes are mainly divided into two categories: internal insulation and filled insulation. Each type of insulation is respectively derived two schemes through changing the thickness of main structure layers and insulation layer. Firstly, we use Weto software to calculate the timber volume of the four schemes, and it concludes that all the optimizations can save more timber than the prototype log wall with the section of 200 mm×200 mm. Secondly, thermal comfort of each scheme is insulated in Design Builder. The results show that thermal insulation of filling type represents better than the other schemes. At last, we use thermal calculating formula to calculate thermal resistance of every scheme. Contrast to the energy efficiency standards of Heilongjiang Province, the data show that the four schemes meet the requirements of the specification.
Key words:  sever cold area  log wall  green wood building  thermal comfort simulation
DOI:10.11916/j.issn.1005-9113.2014.05.008
Clc Number:TU227
Fund:

LINKS