Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
Back Issue    Advanced Search
This paper has been: browsed 2956times   downloaded 2764times  
Shared by: Wechat More
Geometric Calibration Method of Robot Based on Measurement System Including Position and Orientation Parameters
Author NameAffiliationPostcode
Deli Zhang* College of Mechanical and Electrical Engineering,Nanjing University of Aeronautics and Astronautics 210016
Yu Zhu Nanjing Research Institute of Simulation and Technology 210010
Lu Yang Estun Automation Co,Ltd 210026
Zhe Liu Engineering Technology Center,Shenyang Aircraft Company 110850
Abstract:
Industrial robot which can acquire high accuracy has been widely used in automatic assembly. Usually, the geometric parameter of industrial robot should be inspected during manufacturing and application. High precision measurement equipment was utilized to acquire the position and orientation of robot’s end-effector, when calibrating the geometric parameter of robot. A kind of measurement system based on a draw-wire encoder was presented, since the current measurement equipment has some disadvantages, such as the cost and the requirements of working environment are high. According to this kind of measurement system, a sort of geometric calibration method of robot was presented including position and orientation parameters. The uncertain arc length of the cable length between robot end-effector and the measurement can be exactly acquired according to the position and orientation parameters. The pose-solving model of robot end-effector was associated with the kinematic model of robot, and robot’s geometric parameter can be computed by using the least-squares methods. Validate instance was conducted, the result showed that the optimal number of the calibration pose was 47 with little improvement in accuracy, even if increasing the number of calibration pose. Robot calibration experiment was performed and the results showed that the absolute accuracy of robot decreased from 4.32 mm to 0.87 mm after calibration, which improved the robot’s absolute accuracy effectively.
Key words:  Robot Calibration  Industrial robot  Geometric parameter identification  Robot accuracy  Draw-wire encoder
DOI:10.11916/j.issn.1005-9113.2023046
Clc Number:TP24
Fund: