Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:Yu-Hong Ling,Hong-Wei Ma,Shao-Feng Li.Structural Design of a Tall Building with Underpinning Structure in Guangzhou[J].Journal of Harbin Institute Of Technology(New Series),2014,21(6):93-101.DOI:10.11916/j.issn.1005-9113.2014.06.016.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 2358times   downloaded 2079times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Structural Design of a Tall Building with Underpinning Structure in Guangzhou
Author NameAffiliation
Yu-Hong Ling Architectural Design and Research Institute, South China University of Technology, Guangzhou 510640, China 
Hong-Wei Ma School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China 
Shao-Feng Li School of Civil Engineering and Transportation, South China University of Technology, Guangzhou 510640, China 
Abstract:
This paper introduces the structural design optimization of a tall building with reinforced concrete frame-core shear walls in Guangzhou downtown. To decrease the construction cost, wide flat beam with 400 mm×650 mm rectangular cross-section are adopted for main beam. Special measures are used to decrease non-coincident centers of mass and stiffness. Because subway tunnels cross the building underground, inclined columns, the second and third floor underground together function as the underpinning structures. Different from traditional transform beam, the proposed underpinning structures show good performance without using large dimensional bending members. Special attentions should be paid to the beams connecting with the inclined column in the underpinning structures, and these beams show large tensile or compressive forces. Settlement observations after completion construction indicate that the building as well as the proposed design measures work well.
Key words:  tall building  subway tunnel  structural design  underpinning structure
DOI:10.11916/j.issn.1005-9113.2014.06.016
Clc Number:TU318
Fund: