首页 | 官方网站   微博 | 高级检索  
     


Amplitude Control for Ultrasonic Welding of Thermoplastics
Authors:YAN Jiuchun  LI Dongqing  ZHANG Hongkun
Abstract:The stabilization of vibration amplitude is an important factor for assuring welding quality. In this paper, the electric parameter for monitoring the output vibration amplitude of the transducer is determined by the analysis of electromechanical analogy,and matching circuits of constant current for the ultrasonic transducer are analyzed and compared. Series matching circuit is designed and analyzed using the method of impedance transformation. The output vibration amplitude of the transducer can be kept constant when the value of electric parameter for the matching circuit is chosen reasonably. The results of analysis is verified by technological experiments.
Keywords:Ultrasonic welding  thermoplastics  amplitude control  series matching circuit
本文献已被 CNKI 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司    京ICP备09084417号-23