Cu2+和Ni2+对水解-MBR工艺处理效能的影响特性
CSTR:
作者:
作者单位:

(1.哈尔滨商业大学 食品工程学院,哈尔滨150076;2.哈尔滨工业大学 市政环境工程学院,哈尔滨 150090)

作者简介:

黄丽坤(1980—),女,博士,副教授; 赵庆良(1962—),男,教授,博士生导师

通讯作者:

王广智,hitwgz@126.com

中图分类号:

X522

基金项目:

国家重大科技专项(2013ZX07201-007-003); 中国博士后科学基金(2012M510965)


Influence characteristics of Cu2+ and Ni2+ on the treatment efficiency of hydrolysis-MBR process
Author:
Affiliation:

(1.School of Food Engineering, Harbin University of Commerce, Harbin 150076,China; 2.School of Municipal and Environmental Engineering, Harbin Institute of Technology, Harbin 150090, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为降低电镀废水中重金属对生物处理系统的冲击,采用水解-膜生物反应器(MBR)组合工艺对电镀综合废水进行处理,以重金属离子Cu2+、Ni2+为代表,重点研究不同质量浓度的重金属冲击下对水解-MBR工艺处理电镀废水效能的影响,以及水中DOMs与微生物活性的变化情况.结果表明:在Cu2+、Ni2+质量浓度5~20 mg/L冲击下,水解-MBR组合工艺对COD和NH4+-N去除效率分别在75%和45%以上.硝化细菌抗重金属冲击能力较差,水解-MBR组合工艺对重金属Cu2+、Ni2+的耐受质量浓度可达20 mg/L,而单纯MBR工艺仅为10 mg/L.水解反应器可将污水中HPI大部分转化为HPO-A,改善难降解有机物可生化性,芳香族化合物的含量明显降低.随着重金属Cu2+、Ni2+质量浓度的升高,MBR反应器内活性污泥的SOUR值逐步下降,但水解-MBR工艺SOUR受重金属的抑制率均比单独MBR工艺低5%左右.由于水解使重金属毒性减弱,水解-MBR系统中微生物的活性较高,系统中EPS含量和出水质量浓度均显著低于单独MBR工艺,且可以有效减少膜表面胶体物质和溶解性有机物形成,降低污泥滤饼层的形成速度,有效减缓膜污染的速率.

    Abstract:

    In order to reduce the impact of heavy metals on the biological treatment system of electroplating wastewater, a lab-scale process combined with hydrolysis reactor and membrane bioreactor (MBR) was used to treat electroplating wastewater. Taking Cu2+ and Ni2+ as research objects, the effects of different metal concentrations on the electroplating wastewater treatment were studied, and the changes of DOMs and microbial activity in water were analysed simultaneously. The experimental results showed that the removal efficiencies of COD and NH4+-N were above 75% and 45%, respectively, when the concentration of Ni2+and Cu2+ was 5-20 mg/L. Nitrification bacteria's ability to resist heavy metal impact was weak. The tolerance concentration of Ni2+ in hydrolysis reactor combined with MBR was 20 mg/L and only 10 mg/L in MBR. The hydrolysis reactor could convert most of HPI into HPO-A, which could improve the biodegradability of refractory organic compounds, and the content of aromatic compounds was obviously decreased. With the increase of Ni2+ and Cu2+, the SOUR value of activated sludge in MBR reactor was gradually decreased, but the inhibition rate of SOUR in hydrolysis reactor combined with MBR was 5% lower than that in MBR. Due to the hydrolysis, the toxicity of heavy metals decreased. In hydrolysis reactor combined with MBR, the activity of microorganism was higher, and the content of EPS and the effluent concentration were significantly lower than those in MBR. The formation of colloid, dissolved organic matter and sludge cake layer could be reduced effectively, which retarded the rate of membrane fouling.

    参考文献
    相似文献
    引证文献
引用本文

黄丽坤,王广智,李伟,屈凡琦,王敬元,赵庆良. Cu2+和Ni2+对水解-MBR工艺处理效能的影响特性[J].哈尔滨工业大学学报,2017,49(2):62. DOI:10.11918/j. issn.0367-6234.2017.02.011

复制