行人大腿冲击器的生物仿真度
CSTR:
作者:
作者单位:

(1.汽车噪声振动和安全技术国家重点实验室(中国汽车工程研究院股份有限公司和重庆长安汽车股份有限公司), 重庆 401122; 2.汽车零部件先进制造技术教育部重点实验室(重庆理工大学),重庆400054)

作者简介:

胡远志(1977—),男,教授,硕士生导师

通讯作者:

刘西,liuxi@cqut.edu.cn

中图分类号:

U467.1

基金项目:

国家自然科学基金(51405050);2015年重庆市重点产业共性关键技术创新专项(cstc2015zdcy-ztzx60010);2015重庆市基础与前沿研究计划项目 (cstc2015jcyjA00048)


Biofidelity of pedestrian upper leg impactor
Author:
Affiliation:

(1. State Key Laboratory of Vehicle NVH and Safety Technology (China Automotive Engineering Research Institute and Chongqing Changan Automobile Company Limited), Chongqing 401122, China; 2. Key Laboratory of Advanced Manufacture Technology for Automobile Parts(Chongqing University of Technology), Ministry of Education,Chongqing 400054, China)

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    针对汽车行人保护碰撞试验中大腿冲击器的生物力学特性问题,采用THUMS(total human model for safety)人体模型与大腿冲击器进行对比仿真分析.模拟THUMS-SUV行人交通事故,并对THUMS人体模型大腿所受冲击力和弯矩进行了输出.根据事故中行人大腿初始碰撞条件和行人大腿最低能量状态,分别建立两种工况的行人大腿冲击器碰撞模型并进行模拟,对比分析行人大腿冲击器和THUMS人体模型大腿的动态响应、最大瞬间冲击力和最大弯矩.仿真结果表明:相对THUMS人体模型而言,大腿冲击器的最大瞬间冲击力偏高而最大弯矩偏低,行人小腿和上身的运动和接触作用,会影响大腿部位的接触力和最大弯矩,因此大腿冲击器的生物仿真度有待提高.

    Abstract:

    Aiming at the biomechanical characteristics of upper leg impactor in the pedestrian protection collision test, THUMS(total human model for safety) model and upper leg impactor were compared and simulated. Firstly, the THUMS-SUV pedestrian accident is simulated, and the impact force and bending moment of THUMS model of upper leg were output. According to the initial condition and minimum energy status of pedestrian upper leg in the accident, two upper leg impactor collision models were established and simulated. The kinematic behavior, maximum bending moment and maximum impact force between THUMS upper leg and upper leg impactor were compared and analyzed. The result showed that the upper leg impactor had higher impact force, but lower bending moment compared to THUMS model. This paper indicates that, due to movement and contact of lower leg and upper body, the contact force and bending moment of upper leg is affected, which means the biofidelity improvement is needed for the upper leg impactor.

    参考文献
    相似文献
    引证文献
引用本文

胡远志,王波,刘西,廖高健.行人大腿冲击器的生物仿真度[J].哈尔滨工业大学学报,2018,50(1):154. DOI:10.11918/j. issn.0367-6234.201612021

复制
相关视频

分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2016-12-05
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2018-01-11
  • 出版日期:
文章二维码