Quick start-up of external circulation (EC) anaerobic reactor
CSTR:
Author:
Affiliation:

Clc Number:

X703

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The performance efficiency,stability and inner sludge distribution were investigated in the operation of the full-scale EC reactor for brewing wastewater treatment and the key factor to the formation of anaerobic granular sludge was analyzed,which provides the references for the start-up and operation of EC reactor.After operation for 95 d,the influent organic load and removal efficiency were 8.5 kg/(m3·d) and 80% respectively,and the effluent COD was lower than 400 mg/L.Meantime,the granular sludge with size of 0.5-1.0 mm was observed from the heights of 1.2 and 4 m in the EC reactor.The results demonstrate that EC anaerobic reactor using the intermittent-continuous start-up mode for treating the low COD concentration and high flow of brewing wastewater is feasible and the upflow velocity in range of 2.5-5 m/h is helpful to form granular sludge quickly.The experiment validates that the EC anaerobic reactor can start up stably and efficiently in the brewing wastewater treatment.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: May 03,2012
  • Published:
Article QR Code