Mechanical behavior of concrete columns confined by steel bar for prestressed concrete spiral hoops
CSTR:
Author:
Affiliation:

(1.School of Civil Engineering, Harbin Institute of Technology, 150090 Harbin,China;2.China Academy of Building Research, 100013 Beijing, China)

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To explore the method of spiral hoops made of steel bar for prestressed concrete and study the mechanism and failure process of concrete column confined by high-strength spiral hoops, the axial compression test of 24 concrete columns confined by steel bar for prestressed concrete spiral hoops and 4 concrete columns confined by steel rebar are carried out. The results show that the ultimate tensile stress of prestressed concrete spiral hoops can be increased with the concrete strength and the ratio of hoop. Based on the results of test, when the columns under axial compression reach the ultimate bearing capacity, the relationship between the tensile strain of spiral hoops and the degree of constraint is suggested, and the calculation formulas are put forward.

    Reference
    Related
    Cited by
Get Citation
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:
  • Revised:
  • Adopted:
  • Online: May 06,2013
  • Published:
Article QR Code