Indoor air pollutants and their correlation at rural houses in severe cold region in winter
CSTR:
Author:
Affiliation:

(School of Municipal and Environmental Engineering, Harbin Institute of Technology, 150090 Harbin, China)

Clc Number:

X508

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    To explore the indoor air pollution at rural houses in severe cold region in winter, a field study was conducted at 10 rural houses in two villages around Harbin. The indoor pollutants including PM2.5, PM10, CO, CO2, SO2, NOx, TVOC and NH3 were tested and the correlation of pollutants were analyzed. The results showed that PM2.5, PM10, SO2, NOx, CO2 and CO were the main pollutants at rural houses in winter, with the overproof rates of 93%, 75%, 62%, 23%, 99%, 64%, respectively. There were good relations between PM10 and PM2.5, CO and PM2.5, respectively. In addition, the linear correlations were also found between SO2 and CO2, NOx and SO2, respectively. The main test indices of pollutants were given based on the regression analysis results. The test method of pollutants was proposed at rural houses in severe cold region in winter.