Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:ZHENG Wen-zhong,WAN Fu-xiong,LI Shi-guang.Experimental research on refractory performance of reinforced concrete beams strengthened with CFRP sheets bonded with an inorganic adhesive[J].Journal of Harbin Institute Of Technology(New Series),2010,17(4):568-574.DOI:10.11916/j.issn.1005-9113.2010.04.025.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 863times   downloaded 471times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
Experimental research on refractory performance of reinforced concrete beams strengthened with CFRP sheets bonded with an inorganic adhesive
Author NameAffiliation
ZHENG Wen-zhong School of Civil Engineering,Harbin Institute of Technology,Harbin 150090,China 
WAN Fu-xiong School of Civil Engineering,Harbin Institute of Technology,Harbin 150090,China 
LI Shi-guang School of Civil Engineering,Harbin Institute of Technology,Harbin 150090,China 
Abstract:
To meet the requirement of fire endurance for concrete structures strengthened with CFRP sheets, this study develops an inorganic adhesive whose strength at 600 ℃ is not lower than that at normal room temperature. The inorganic adhesive is then used to bond CFRP sheets on reinforced concrete beams in order to strengthen them. The fire protection of the CFRP sheets is done using the thick-type fireproofing coatings for tunnel (TFCT) and steel structure (TFCSS) respectively. Four specimens are tested in the furnace together. Specimens are exposed to fire for 1. 5 h in according to the ISO834 standard fire curve,and then naturally cooled for 1 h. In the tests,the largest displacements at the mid-span positions of specimens are only from 1 /1400 to 1 /318 of actual span corresponding to the highest temperatures from 300 ℃ to 470 ℃. After the specimens are naturally cooled to the normal temperature and the fireproofing coatings are then removed,it can be seen that the CFRP sheets keep in a good state,which indicates that CFRP sheets can be tightly bonded on the concrete and work well together with the concrete beams during and after fire. Besides,the tests also verify that the fire performance of TFCT is superior to TFCSS for the strengthened beams.
Key words:  fire performance  reinforced concrete beam  CFRP sheets  fireproofing coating  test
DOI:10.11916/j.issn.1005-9113.2010.04.025
Clc Number:TU375.1
Fund:

LINKS