Please submit manuscripts in either of the following two submission systems

    ScholarOne Manuscripts

  • ScholarOne
  • 勤云稿件系统

  • 登录

Search by Issue

  • 2024 Vol.31
  • 2023 Vol.30
  • 2022 Vol.29
  • 2021 Vol.28
  • 2020 Vol.27
  • 2019 Vol.26
  • 2018 Vol.25
  • 2017 Vol.24
  • 2016 vol.23
  • 2015 vol.22
  • 2014 vol.21
  • 2013 vol.20
  • 2012 vol.19
  • 2011 vol.18
  • 2010 vol.17
  • 2009 vol.16
  • No.1
  • No.2

Supervised by Ministry of Industry and Information Technology of The People's Republic of China Sponsored by Harbin Institute of Technology Editor-in-chief Yu Zhou ISSNISSN 1005-9113 CNCN 23-1378/T

期刊网站二维码
微信公众号二维码
Related citation:Qichang An,Jingxu Zhang,Fei Yang,Hongchao Zhao.TMT Tertiary Mirror Optical Jitter Model Metrology[J].Journal of Harbin Institute Of Technology(New Series),2016,23(6):67-72.DOI:10.11916/j.issn.1005-9113.2016.06.010.
【Print】   【HTML】   【PDF download】   View/Add Comment  Download reader   Close
←Previous|Next→ Back Issue    Advanced Search
This paper has been: browsed 1341times   downloaded 1491times 本文二维码信息
码上扫一扫!
Shared by: Wechat More
TMT Tertiary Mirror Optical Jitter Model Metrology
Author NameAffiliation
Qichang An Changchun Institute of Optics, Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China
Graduate University of Chinese Academy of Sciences, Beijing 100039, China 
Jingxu Zhang Changchun Institute of Optics, Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China 
Fei Yang Changchun Institute of Optics, Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China 
Hongchao Zhao Changchun Institute of Optics, Fine Mechanics and Physics,Chinese Academy of Sciences,Changchun 130033,China 
Abstract:
To measure the jitter performance of the Tirthy Meter Telescope tertary mirror(TMT M3), the model of jitter based on the accerleration signal is established. First and foremost, the procedure TMT required to processs the jitter data is presented. Then, the jitter of the system is divided into two parts: powered jitter and unpowered jitter. The metric of the jitter is required to be in the form of displacement or angle. So the frequency integration is involved to minify the error source introduced by the tending iterm in the time domain integration. In the evaluation of the power jitter, the accelerometers are used to obtain the rigid body motion of the tertiary mirror. The random decrement technique and dominated mode theory are applied to obtain the model of unpowered jitter. A classical telescope performances a 1.6” RMS jitter metric; for a four meter scale system, the resonance frequency is around 107 Hz, powering, with 0.14% damping. Consequently, the tip (183 Hz,0.6%) and tilt (193 Hz, 0.19%) are both be measured. Using this model, the system engineers can estimate the unpowered jitter when the system is presented in the distortion.
Key words:  TMT M3  numerical integration  jitter  transfer function  power spectral density  wind load
DOI:10.11916/j.issn.1005-9113.2016.06.010
Clc Number:TH751
Fund:

LINKS