摘要: |
为了解决桩基检测中长桩桩底与深部缺陷难以识别的问题,采用旁孔透射波法,建立桩-土系统简化理论模型,对旁孔透射波法提出了桩身缺陷及桩底深度的检测分析方法,并采用三维轴对称有限元模型,对比分析了旁孔透射波法与低应变反射波法检测的技术效果.结果表明,反射波法适用于非长桩的长度和深度不大的桩身缺陷检测,虽然指数放大有助于辨识长桩底端和较深处桩身缺陷的反射信号,但在实际应用中仍会存在一定的不确定性.旁孔透射波法受桩长和长径比的影响显著小于反射波法,在桩身缺陷位置及其程度和桩底深度的检测分析中更具优势. |
关键词: 旁孔透射波法 反射波法 基桩 桩身缺陷 桩端深度 |
DOI:10.11918/j.issn.0367-6234.2013.08.016 |
分类号: |
基金项目:国家自然科学基金(51178267);交通运输部西部交通科技项目(20113182231390). |
|
Comparison of parallel seismic and reflected wave tests for piles |
ZHANG Jingyi1, CHEN Longzhu1, SONG Chunxia2, MA Ye2
|
(1.Institute of Engineering Safety and Disaster Prevention, Shanghai Jiao Tong University, 200240 Shanghai, China; 2.Research Institute of Highway Ministry of Transport, 100088 Beijing, China)
|
Abstract: |
For solving the difficulties in evaluation of the pile tip embedded depth for a long pile and depth of a deep embedded defect, the parallel seismic test is proposed in this paper. A simplified theoretical model of pile-soil system is established to determinate embedded depths of the pile tip and defect. Three-dimensional (3-D) axisymmetric finite element models were established for comparison of the parallel seismic (PS) and the reflected wave (RW) tests for piles. It was found that the RW test was suitable for determination tip embedded depth of a non-long pile and a non-deep embedded defect of a pile. Exponential amplification could be employed to deal with such difficulties, but still there were uncertainties existing in practical application. Compared to RW test, PS test is much less affected by pile length and depth-to-diameter ratio, and has advantages in identifying the embedded depth and degree of a defect as well as the embedded depth of the pile tip. |