引用本文: | 苏利鹏,杜谦,王义德,李喜梅,王敏,高建民,董芃.二氧化硫在氯化钙盐吸法应用中的反应特性[J].哈尔滨工业大学学报,2018,50(11):178.DOI:10.11918/j.issn.0367-6234.201712012 |
| SU Lipeng,DU Qian,WANG Yide,LI Ximei,WANG Min,GAO Jianmin,DONG Peng.Reactive characteristics of sulfur dioxide in the application of calcium chloride absorption method[J].Journal of Harbin Institute of Technology,2018,50(11):178.DOI:10.11918/j.issn.0367-6234.201712012 |
|
|
|
本文已被:浏览 1681次 下载 1098次 |
码上扫一扫! |
|
二氧化硫在氯化钙盐吸法应用中的反应特性 |
苏利鹏1,杜谦1,王义德1,2,李喜梅1,王敏1,高建民1,董芃1
|
(1.哈尔滨工业大学 能源科学与工程学院, 哈尔滨 150001; 2.燕山大学 车辆与能源学院, 河北 秦皇岛 066004)
|
|
摘要: |
为探索氯化钙盐吸条件下SO2可能的转化反应以及该类反应对氯化钙盐吸法测量烟气中SO3的影响特性, 采用一维立卧管式炉实验装置及控制变量法研究了水蒸气、氧气氛、温度、反应物浓度对SO2与CaCl2化学反应的影响, 并理论分析了SO2与CaCl2可能的化学反应过程及对SO3测量的影响.结果表明:在无CaCl2样品条件下, SO2并不能发生均相反应; 在典型氯化钙盐吸法条件下, 只有当H2O及O2同时存在时, SO2可与CaCl2发生明显化学反应; 升高立卧管式炉温度及增加反应物浓度, SO2的转化率相应升高, 转化率约在2 %~8 %; 理论分析表明,该反应在200 ℃及典型取样气氛下属于慢化学反应, 在高浓度硫酸蒸汽存在下被严重抑制, 减小了对SO3测量的干扰, 一定程度上证明了氯化钙盐吸法测量SO3的可行性.
|
关键词: SO2 SO3 CaCl2 盐吸收法 硫酸雾 非均相反应 缩芯模型 |
DOI:10.11918/j.issn.0367-6234.201712012 |
分类号:TK314 |
文献标识码:A |
基金项目:国家科技支撑计划项目(2014BAA07B03); 国家自然科学基金创新群体项目(51421063) |
|
Reactive characteristics of sulfur dioxide in the application of calcium chloride absorption method |
SU Lipeng1,DU Qian1,WANG Yide1,2,LI Ximei1,WANG Min1,GAO Jianmin1,DONG Peng1
|
(1. School of Energy Science and Engineering, Harbin Institute of Technology, Harbin 150001, China; 2. College of Vehicles and Energy, Yanshan University, Qinhuangdao 066004,Hebei , China)
|
Abstract: |
The main objectives are to explore the possible SO2 conversion reactions under the condition of calcium chloride absorption method (CCAM) and the effects of these reactions on SO3 measurement by the CCAM. The vertical-horizontal tube furnace and variable-controlling approach were used to study the influences of water vapor, oxygen atmosphere, temperature, reactant concentration on the chemical reaction between SO2 and CaCl2. On this basis, the possible chemical reaction mechanisms of SO2 and CaCl2 and the effects on SO3 measurement were analyzed theoretically. The results showed that SO2 could not undergo the homogeneous reactions in the absence of CaCl2. Under typical conditions of CCAM, only when H2O and O2 existed simultaneously, an obvious chemical reaction between SO2and CaCl2could occur. The conversion rate of SO2 can be improved with the increase of temperature and reactant concentration and the conversion rate is 2% to 8% approximately. Finally, the theoretical analysis demonstrated that the heterogeneous reaction was extremely week at 200 ℃and under typical sampling atmosphere, and this reaction was severely inhibited in the presence of high concentration of gaseous H2SO4. Therefore, the effect of SO2 interference on SO3 measurement could be ignored, which proved the feasibility of the CCAM to some extent.
|
Key words: SO2 SO3 Calcium Chloride salt absorption method sulfuric acid mist heterogeneous reaction shrinking core model |
|
|
|
|